  1.  
  2. This will dismiss the dialog, and begin a full-resolution scan;  so make sure that all of your settings are correctly entered.
  3.  
  4.  
  5.  
  6.  
  7. When the "Auto" checkbox is selected, an autoexposure will be performed AT LEAST once for a piece of film.
  8.  
  9.  
  10. If you double-click here, the crop will expand to full selection.  If you hold down the shift key and double-click, a preview is made.  If you hold down the command key, a scan is made.
  11.  
  12.  
  13. This will fill the crop selection area with a small image from the scanner.  Once the image has been acquired, you may use it as a "thumbnail" of the final scan.
  14.  
  15.  
  16. Monochrome previews on 3-pass scanners can be faster, so if all you want to do is to select a crop, you may not need a full-color preview.
  17.  
  18.  
  19. This allows you to have an "home" state, to which you will return whenever you hit the "Reset" button.
  20.  
  21.  
  22. This will erase the preview, so be sure that you want to reset the dialog settings.
  23.  
  24.  
  25. If there is no autoloader attached, the scanner will ignore this.
  26.  
  27.  
  28. For the LS-3510AF, this menu allows registration of color negative film types.  Select the "Register‚Ķ" item, and pay close attention to the instructions in the dialog that appears.
  29.  
  30.  
  31. If file size is locked, and you select "Pixels" as the units, you will not be able to change the width in the edit text item.
  32.  
  33.  
  34. If file size is locked, and you select "Pixels" as the units, you will not be able to change the height in the edit text item.
  35.  
  36.  
  37. This is output resolution, and should not be confused with scan resolution.  You should enter the resolution of your intended display or hardcopy device into the associated edit text item.
  38.  
  39.  
  40. If file size is locked, and you select "Pixels" as the units, you will not be able to change the width in the edit text item.
  41.  
  42.  
  43. If file size is locked, and you select "Pixels" as the units, you will not be able to change the height in the edit text item.
  44.  
  45.  
  46. This is output resolution, and should not be confused with scan resolution.  You should enter the resolution of your intended display or hardcopy device into the edit text item.
  47.  
  48.  
  49. Scan pitch is a number that is the denominator in a fraction indicating what proportion of the total available scanner resolution will be needed for the scan.  1 = Full resolution, 2 = 1/2, 4 = 1/4, etc‚Ķ
  50.  
  51.  
  52. If you select this, and type a number into the Height and/or Width items, the crop will not change.  Otherwise, the crop will always change to follow new Height/Width values.
  53.  
  54.  
  55. This constrains the Height, Width and Output Resolution items.  If Pixels are selected as Height and/or Width units, their values will not be allowed to be changed.
  56.  
  57.  
  58.  
  59.  
  60. When you adjust this, the focus scan will update to reflect the new focus value.
  61.  
  62.  
  63. When you change the value of this, the focus scan will update to reflect the new focus value.
  64.  
  65.  
  66.  
  67.  
  68.  
  69.  
  70. Adjusting this will make the entire image lighter or darker.
  71.  
  72.  
  73. If we are adjusting contrast, we will enhance or hide detail in the shadows and highlights.  If we are adjusting black level, we will mainly affect contrast in the shadows.
  74.  
  75.  
  76.  
  77.  
  78.  
  79.  
  80.  
  81.  
  82. An autoexposure should be made whenever a new piece of film is inserted, as the scanner needs to measure each individual image for densitometric characteristics.
  83.  
  84.  
  85. The scanner makes a densitometric characterization of the image, and will adjust internal analog parameters to maximize scan quality.
  86.  
  87.  
  88. The scanner almost always gets it's focus right.  In the rare cases where it is unable to do this, use the Manual Focus controls.
  89.  
  90.  
  91. This causes the displayed (and scanned) image to be rotated by 90¬∞.
  92.  
  93.  
  94. If you are not very familiar with the technical operation of the scanner, you should not use the "Service" items.
  95.  
  96.  
  97.  
  98.  
  99.  
  100.  
  101.  
  102.  
  103.  
  104.  
  105.  
  106.  
  107.  
  108.  
  109.  
  110.  
  111.  
  112.  
  113.  
  114.  
  115.  
  116.  
  117.  
  118.  
  119.  
  120.  
  121.  
  122.  
  123.  
  124.  
  125.  
  126.  
  127.  
  128.  
  129. For the LS-3510AF, this menu allows registration of your color negative film type.  Select the "Register‚Ķ" item, and pay close attention to the instructions in the dialog that appears.
  130.  
  131.  
  132. If you are using an LS-3510AF, or are in "Scanning Focus" mode, the cursor will turn into a magnifying glass when over the crop area.  Select a spot to "zoom" in on for a focus.
  133.  
  134.  
  135.  
  136.  
  137.  
  138.  
  139.  
  140.  
  141.  
  142.  
  143.  
  144.  
  145.  
  146.  
  147.  
  148.  
  149. The scanner will scan more slowly for non-integer scan pitch values.
  150.  
  151.  
  152.  
  153.  
  154. You may save as many settings files as you would like.  This is a convenient way to have many preset dialog conditions available.
  155.  
  156.  
  157. When the new settings are loaded, the preview will be erased, so make sure that you want this to happen.
  158.  
  159.  
  160. This will be a new dialog that will allow you to create your own set of tables to be used in place of the scanner's internal tables, if the "User-Defined Curves" checkbox is selected.
  161.  
  162.  
  163.  
  164.  
  165.  
  166.  
  167.  
  168.  
  169.  
  170.  
  171.  
  172.  
  173.  
  174.  
  175.  
  176.  
  177. If file size is locked, and you select "Pixels" as the units, you will not be able to change the width in the edit text item.
  178.  
  179.  
  180. If file size is locked, and you select "Pixels" as the units, you will not be able to change the height in the edit text item.
  181.  
  182.  
  183. This is output resolution, and should not be confused with scan resolution.  You should enter the resolution of your intended display or hardcopy device into the associated edit text item.
  184.  
  185.  
  186. Scan pitch is a number that is the denominator in a fraction indicating what proportion of the total available scanner resolution will be needed for the scan.  1 = 100%, 2 = 50% etc‚Ķ
  187.  
  188.  
  189.  
  190.  
  191.  
  192.  
  193.  
  194.  
  195.  
  196.  
  197.  
  198.  
  199.  
  200.  
  201.  
  202.  
  203.  
  204.  
  205.  
  206.  
  207.  
  208.  
  209.  
  210.  
  211.  
  212.  
  213.  
  214.  
  215.  
  216.  
  217.  
  218.